Lennox Low Ambient Kit Wiring Diagram

Installation Instructions for Low Ambient Kit Used on KGKCKHKD Packaged Units

Disclaimer

Please note that these instructions are for qualified technicians only. If you are not comfortable performing these tasks, please contact a licensed HVAC professional for assistance.

Typical Installation of Low Ambient Pressure Switch S11 and Relay K58

  1. Pressure Switch Wiring
    • Disconnect wires marked S11 as shown in figure 7 for ZGZC units and figure 9 for KGKC.
  2. Relay Wiring
    • Check if the unit has a mechanical fitting high-pressure switch. If not, install a tee fitting on the condensing unit liquid.
    • Remove the plastic plug from P4-4 on the circuit board.
    • Connect the brown wire from the low-pressure switch to terminal 4 of the relay.
    • Connect the black wire from the low-pressure switch to terminal 5 of the relay.
    • Connect the red wire to terminal 6 of the relay and then to terminal 1 of the compressor contactor.
  3. Ambient Temperature Sensor
    • Insert the ambient temperature sensor into the plug located at P4-4.
  4. Electrical Connections
    • Connect the power supply wires to the unit as per the wiring diagram.
    • Connect the 240V terminal to the 208V terminal as shown on the wiring diagram.
  5. Final Checks
    • Ensure all electrical connections are secure.
    • Turn on the power to the unit and check for proper operation.

NOTE: Use ONLY expansion valve metering devices on units with low ambient kits.

Additional Information

For more detailed instructions, please refer to the Lennox Low Ambient Kit 16F24 -- ELS120-150 Installation Manual.